- MAIFI
- MAIFI EE s. → momentary average interruption frequency index
English-German dictionary of Electrical Engineering and Electronics. 2013.
English-German dictionary of Electrical Engineering and Electronics. 2013.
MAIFI — The Momentary Average Interruption Frequency Index (MAIFI) is a reliability indicator used by electric power utilities. MAIFI is the average number of momentary interruptions that a customer would experience during a given period (typically a… … Wikipedia
SAIDI — The System Average Interruption Duration Index (SAIDI) is commonly used as a reliability indicator by electric power utilities. SAIDI is the average outage duration for each customer served, and is calculated as:mbox{SAIDI} = frac{mbox{sum of all … Wikipedia
SAIFI — The System Average Interruption Frequency Index (SAIFI) is commonly used as a reliability indicator by electric power utilities. SAIFI is the average number of interruptions that a customer would experience, and is calculated asmbox{SAIFI} =… … Wikipedia
CAIDI — The Customer Average Interruption Duration Index (CAIDI) is a reliability index commonly used by electric power utilities. It is related to SAIDI and SAIFI, and is calculated asmbox{CAIDI} = frac{mbox{sum of all customer interruption… … Wikipedia
Outage management system — An Outage Management System (OMS) is a computer system used by operators of electric distribution systems to assist in restoration of power. Contents 1 Major Functions of an OMS 2 OMS Principles and Integration Requirements 3 OMS Benefits … Wikipedia
CAIFI — The Customer Average Interruption Frequency Index (CAIFI)[1] is a popular index used in electrical reliability analysis.[2] It is designed to show trends in customers interrupted and helps to show the number of customers affected out of the whole … Wikipedia